Feutron climate test chamber with humidity control, temperature range -40 ... +100°C, volume 2.0 m³,Feutron
Klimaprüfkammer
Feutron climate test chamber with humidity control, temperature range -40 ... +100°C, volume 2.0 m³,
Feutron
Klimaprüfkammer
Fiksna cena plus PDV
15.000 €
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
- Oznaka mašine:
- Feutron climate test chamber with humidity control, temperature range -40 ... +100°C, volume 2.0 m³,
- Proizvođač:
- Feutron
- Model:
- Klimaprüfkammer
- Stanje:
- polovno
Cena i lokacija
Fiksna cena plus PDV
15.000 €
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozvati
Detalji ponude
- ID oglasa:
- A22148202
- Referentni broj:
- 23444
- Ažuriranje:
- последњи пут дана 30.10.2026
Opis
Feutron
Type: 3702/06
Water-cooled climate testing chamber
Technical data:
Test chamber nominal volume: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width: 2000 mm, height: 1000 mm
Viewing window: heated, 2 pieces, width: 500 mm, height: 600 mm
Feedthrough opening: 1 piece, left side wall, diameter: 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Bodpfx Aszd Sdmjkpoww
Temperature difference, over time: ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling: up to 2.0 K/min on average
Heating: up to 2.0 K/min on average
Humidity range: 10...95 % r.h.
Humidity difference, over time: ≤ ± 3.0 % r.h.
Dew point range, intermittently: -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and drying refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/, 50Hz
Power plug: CEE 5-pole, 32 A, with 5.0 m cable
Max. simultaneous power consumption: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Oglas je automatski preveden. Moguće su greške u prevodu.
Type: 3702/06
Water-cooled climate testing chamber
Technical data:
Test chamber nominal volume: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width: 2000 mm, height: 1000 mm
Viewing window: heated, 2 pieces, width: 500 mm, height: 600 mm
Feedthrough opening: 1 piece, left side wall, diameter: 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Bodpfx Aszd Sdmjkpoww
Temperature difference, over time: ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling: up to 2.0 K/min on average
Heating: up to 2.0 K/min on average
Humidity range: 10...95 % r.h.
Humidity difference, over time: ≤ ± 3.0 % r.h.
Dew point range, intermittently: -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and drying refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/, 50Hz
Power plug: CEE 5-pole, 32 A, with 5.0 m cable
Max. simultaneous power consumption: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)